Storage
Storage
Short Term Storage
(up to 2 days)
1.Relieve pressure, page 10.
2.Leave suction tube and prime tube in paint pail.
ti9353b
3.Cover paint pail and hoses tightly with plastic wrap.
ti9350a
4.
a.Engage trigger lock.
b.Leave gun attached to
hose.ti8908a
c.If you have not already cleaned them, remove
tip and guard from gun and clean with water or flushing solvent. A soft
brush can be used to ti9671a loosen and remove
dried on material if needed.
d.Wipe paint off outside of gun using a soft cloth moistened with water or flushing sol- vent.
Long Term Storage
(more than 2 days)
Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will cor- rode and damage pump. Follow Shutdown and Cleaning, page 17, or Power Flush Cleaning, page 19.
1.Place suction tube in Pump Armor storage
fluid bottle and prime tube in waste pail.
ti2057a
2.Turn Prime/Spray valve to PRIME.
ti9346a
3. Turn power switch ON.
ti5580a
4.Turn pressure control knob clockwise until the pump turns on.
ti9343b
5. When storage fluid comes out of prime tube
ti2018a
6.Turn Prime/Spray valve to SPRAY to keep storage fluid in sprayer during storage.
ti9345a
22 | 312001R |