Repair
Section 4: Purging Air After Adding or Replacing a Master Divider Valve Module
LUBE POINT
SECONDARY
MASTER | DISCONNECT | HAND PUMP | BLEED | |
HERE | ||||
| LINE | |||
|
|
|
NEW VALVE
BLOCK
TI11116
FIG. 9
Steps
1.Install the new or replacement module into the mas- ter divider valve assembly. Also connect the tubing or hoses to the appropriate secondary divider valve(s) or lubrication point(s) if the new/replace- ment module is a base section.
2.Do not completely tighten the connection(s) at the secondary divider valve’s inlet or at lubrication points.
3.Disconnect and remove the line from the pump at the inlet of the master divider valve.
4.Attach a hand pump filled with clean, filtered lubri- cant to the inlet port on the master divider valve.
5.Operate the hand pump until
6.Tighten the fitting at the secondary valve inlet or at the lubrication port while lubricant is still flowing.
7.Remove the hand pump and reconnect the system pump to the inlet of the master divider valve.
The system is now ready for operation.