4.Install extension (102) to meter:
a.Loosen extension nut (102a) (FIG. 4) until it is completely off tube threads.
102
102a
FIG. 4
NOTE: Do not use PTFE tape or thread sealant on threads of extension (102). This could cause the fitting to leak.
b.Thread extension (102) into meter housing as shown in FIG. 5 until it bottoms out.
102
FIG. 5
c.Align extension (102) with meter housing and handle. Hand tighten extension nut (102a).
FIG. 6
Installation
d. Wrench tighten extension nut (102a).
5.Install nozzle (101):
NOTE: Do not use PTFE tape or thread sealant on threads of nozzle (101). This could cause the fitting to leak.
a.Thread nozzle (101) onto extension (102) as shown in FIG. 7.
.
102
101
101a
FIG. 7
b.Use an
•Only tighten nozzle with wrench on flats of the nozzle bushing.
•Do not disassemble the bushing from noz- zle. Disassembly will affect performance of the nozzle.
333492B | 11 |