4.Install extension (102) to meter:

a.Loosen extension nut (102a) (FIG. 4) until it is completely off tube threads.

102

102a

FIG. 4

NOTE: Do not use PTFE tape or thread sealant on threads of extension (102). This could cause the fitting to leak.

b.Thread extension (102) into meter housing as shown in FIG. 5 until it bottoms out.

102

FIG. 5

c.Align extension (102) with meter housing and handle. Hand tighten extension nut (102a).

FIG. 6

Installation

d. Wrench tighten extension nut (102a).

5.Install nozzle (101):

NOTE: Do not use PTFE tape or thread sealant on threads of nozzle (101). This could cause the fitting to leak.

a.Thread nozzle (101) onto extension (102) as shown in FIG. 7.

.

102

101

101a

FIG. 7

b.Use an open-end adjustable wrench on flats of nozzle bushing (101a) (FIG. 7) to tighten fitting.

Only tighten nozzle with wrench on flats of the nozzle bushing.

Do not disassemble the bushing from noz- zle. Disassembly will affect performance of the nozzle.