6.Install small retaining ring (43), pointer pin (41) and pointer spring (42). Install the cover (44). (FIG. 25).
43 44
42
41
FIG. 25
SDMP8 Preset Meter Counter Section Repair
Disassembly
NOTE: Do not disassemble the fluid and counting sec- tions simultaneously. Confirm the fluid section is fully assembled before removing the counting section.
1.Relieve pressure, page 8.
2.Remove the cover (44), small retaining ring (43), (FIG. 26).
44
43
FIG. 26
Service
3.Remove the needle pointer (41), springs (39) and pins (40) (FIG. 27).
41
39/40
FIG. 27
4.Remove the large retaining clip (38) and then the face plate panel (37) (FIG. 28).
38
37
FIG. 28
5.Use a 2 mm hex wrench to remove the gear set- screw (33). Remove the gears (32, 34) (FIG. 29).
34
3332
FIG. 29
333492B | 17 |