Relieve pressure, page 8, before you check or repair the meter. Be sure all other valves, controls and pump are operating properly.

Problem

Cause

Solution

 

 

 

 

 

1. Relieve pressure, page 8.

 

 

2. Remove meter from hose.

 

 

3. Clean or replace strainer (3a).

 

Strainer (3a) is clogged.

4. Install meter to hose (See Installing

 

 

Meter, page 10).

 

 

5. If the problem remains, contact your

 

 

Graco distributor for repair or

 

 

replacement.

 

 

 

Slow or no fluid flow.

Pump pressure is low.

Increase pump pressure.

 

 

Twist lock nozzle not fully open.

Aim nozzle into bucket. Fully open noz-

 

 

 

zle.

 

 

Do not trigger meter when nozzle is

 

 

closed! If you do accidentally trigger

 

 

the meter with the nozzle closed, point

 

 

nozzle into a waste bucket and slowly

 

 

open the nozzle to relieve pressure and

 

 

expel built up fluid.

 

 

 

 

Fluid shut-off valve (J or L) is not fully open

Fully open fluid shut-off valve (J or L).

 

(page 9).

 

 

 

 

 

Foreign material is wedged in the meter

Contact your Graco distributor for repair

 

housing.

or replacement.

 

 

 

Meter leaks from twist lock nozzle.

Twist lock nozzle has a damaged seal.

Replace nozzle. See Step a in Installa-

It is important to distinguish

 

tion Procedure, page 11.

 

 

between the two causes of this

Valve has damaged or obstructed seals.

Clean valve assembly or replace.

problem. A new nozzle will NOT

 

 

correct a fluid leak caused by a

 

 

faulty valve.

 

 

 

 

 

 

Poor swivel/hose connection.

Apply PTFE tape (leave a minimum 2

 

 

engaged threads uncovered for electri-

 

 

cal continuity) or sealant to threads of

 

 

hose and tighten the connection. See

Meter leaks from swivel.

 

Step 2 in Installation Procedure, page

 

 

10.

 

 

 

 

Poor swivel/meter housing connection.

Torque the fitting to 20-25 ft.-lbs.

 

 

 

 

Swivel seals have deteriorated and leak.

Replace swivel.

 

 

 