Technical Data
Technical Data
Manual and Preset Meter
| US |
| Metric |
Flow rate* | 0.26 to 8 gpm |
| 1 to 30 lpm |
Maximum working pressure | 1500 psi |
| 10 MPa, 103.4 bar |
|
|
|
|
Weight |
|
|
|
Manual Meter | 3.42 lbs |
| 1.55 kg |
Preset Meter | 3.50 lbs |
| 1.58 kg |
|
|
|
|
Dimensions (without extension) (see page 27) |
|
|
|
Length | 11.4 inches |
| 28.9 cm |
Width | 3.94 inches |
| 10 cm |
|
|
|
|
Height Manual Meter | 4.85 inches |
| 12.3 cm |
Height Preset Meter | 6.33 inches |
| 16.08 cm |
Maximum Totalizer Digits |
| 99,999 units** | |
|
|
| |
Inlet |
| ||
|
| ||
|
| ||
|
| ||
Outlet | |||
Operating temperature range |
| ||
Wetted parts | brass, aluminum, stainless steel, TPE | ||
|
| ||
Fluid compatibility | antifreeze, gear oil, crankcase oil | ||
Meter pressure loss |
| 30 psi @ 4 gpm | |
Accuracy - Manual Meter: Oil |
| +/- 1 percent | |
|
|
| |
Accuracy - Manual Meter: Antifreeze |
| +/- 3 percent | |
Accuracy - Preset Meter: Oil or Antifreeze |
| +/- 3 percent | |
|
|
|
|
*Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity. **Rolls over to 00,000 after maximum value is reached.
26 | 333492B |