Basic Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Pump does not prime.

Prime/Spray Valve is in SPRAY posi-

Turn Prime/Spray Valve to PRIME

 

tion.

position (pointing down).

 

 

 

 

Inlet screen is clogged or suction

Clean debris off inlet screen and

 

tube is not immersed.

make sure suction tube is immersed

 

 

in fluid.

 

 

 

 

Pump was not primed with flushing

Remove suction tube from paint.

 

fluid.

Prime pump with water or

 

 

solvent-based flushing fluid, see

 

 

Operation manual 312001.

 

 

 

 

Inlet valve check ball is stuck.

Remove suction tube and place a

 

 

pencil into the inlet section to dis-

 

 

lodge the ball, allowing pump to

 

 

prime properly. Or, Power Flush

 

 

sprayer, see Operation manual

 

 

312001.

 

 

 

 

 

AutoPrime may need replacement.

 

 

Turn power switch ON and listen for

 

 

“tap” in pump. If you do not hear

 

 

“tap”, AutoPrime is damaged. Take

 

 

sprayer to Graco/MAGNUM autho-

 

 

rized service center.

 

 

 

 

Inlet valve check ball or seat is dirty

Remove inlet fitting. Clean or replace

 

 

ball and seat.

 

 

 

 

Outlet valve check ball is stuck.

ProX7 and ProX9: Insert screw

 

 

driver in slot and remove

 

 

Easy-Access door, page 7. Unscrew

 

 

outlet valve with a 3/4 in. socket.

 

 

Remove and clean assembly.

 

 

X5 and X7: Remove outlet fitting and

 

 

clean outlet check ball.

 

 

 

 

Suction tube is leaking.

Check suction tube for cracks and

 

 

cuts. Make sure suction tube clamp is

 

 

on hose. Replace suction tube if

 

 

cracked or damaged.

 

 

 