Installation
Grounding and Electric
Requirements
Sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for electrical current due to static build up or in the event of a short circuit.
•This sprayer requires a 120 Vac, 60 Hz, 15A circuit with a grounding receptacle.
•Never use an outlet
that is not grounded | ti5573a |
or an adapter. |
|
•Do not use the sprayer if the electrical cord has a damaged ground prong.
• Only use an extension cord with an undamaged
ti5572a
Recommended extension cords for use with this sprayer:
•50 ft (15.0 m) 14 AWG (2.1 mm2)
•100 ft (30.0 m) 12 AWG (3.3 mm2)
Spray gun: ground through connection to a properly grounded fluid hose and pump.
Smaller gauge or longer extension cords may reduce sprayer performance.
Installation
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.
Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.
Maintaining grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.
ti9207a
Thermal Overload
Motor has a thermal overload switch to shut itself down if overheated. If unit overheats, allow approximately 45 minutes for unit to cool. Once cool, switch will close and unit will restart.
To reduce risk of injury from motor starting unexpect- edly when it cools, always turn power switch OFF if motor shuts down.