Advanced Troubleshooting

General Problem: Low or Fluctuating Output

Specific Problem

Cause

Solution

 

 

 

 

 

 

Pump cycles, but output is low or

See Basic Troubleshooting,

 

surging.

page 11.

 

 

 

 

 

Worn or obstructed inlet and

Check for worn pump valves as follows:

 

outlet valves.

Prime sprayer with paint. Turn the Prime/Spray valve

 

 

 

 

to SPRAY position. Turn pressure control fully

 

 

clockwise.

 

 

Trigger spray gun briefly.

 

 

When spray gun trigger is released pump should

 

 

cycle momentarily and stop.

 

 

If pump continues to cycle, pump valves may be

 

 

worn or obstructed.

 

 

For replacement inlet and outlet valve kits, see List

 

 

of Kits, page 26.

 

 

 

 

Prime/Spray valve is leaking out

Check Prime/Spray valve for debris trapped on seat

 

drain line when Prime/Spray

and for worn parts. Torque to 130-180 in-lb

 

valve is in SPRAY position.

(15.8-18.1 N•m). Replace if parts are worn using

 

 

Prime/Spray Valve Kit, page 26.

 

 

 

 

Voltage from electrical outlet is

Check voltage of outlet. Meter must read 85 to 130V

 

too low. Low voltages reduce

AC.

 

sprayer performance.

 

 

 

 

 

Extension cord is too long or not

Replace extension cord.

 

heavy enough gauge.

See Grounding and Electrical Requirements,

 

 

 

 

page 6.

 

 

 

 

Leads from motor or pressure

Be sure terminals are centered and firmly

 

switch to control board are

connected. Inspect for pinched wiring and wiring

 

damaged, loose, pinched, or

insulation and terminals for signs of overheating.

 

overheated.

Replace any loose terminals or damaged wiring.

 

 

Securely reconnect terminals.

 

 

 

 

Motor brushes are worn.

Check length of BOTH brushes (brushes do not

 

 

wear evenly on both sides of the motor). Brush

 

 

length must be 0.25 in. (6.4mm). If brushes are worn

 

 

replace motor using Motor Kit, page 26.

 

 

 

 

Motor brush springs are broken.

If springs are broken, replace motor using Motor Kit,

 

 

page 26.

 

 

 

 

Motor brushes are binding in

Clean brush holders. Remove carbon dust with small

 

brush holders.

cleaning brush.

 

 

 

 

Motor stops before sprayer

Replace pressure control using Pressure Control

 

reaches correct pressure (stall

Switch Kit, page 26.

 

pressure is too low).

 

 

 

 

 

Control board is damaged.

See Control Board Diagnostics, page 25. If

 

CAUTION: Do not perform

damaged, replace control board using Control

 

Board Kit, page 26.

 

control board diagnostics until

 

 

you have determined the

 

 

armature is good. A damaged

 

 

armature can burn out a good

 

 

control board.

 

 

 

 

312667B

21