Graco Inc 261820 specifications General Problem Excessive Pressure Build Up, Control Switch Kit

Models: 261820

1 40
Download 40 pages 2.27 Kb
Page 22
Image 22

 

 

Advanced Troubleshooting

 

 

 

 

 

 

 

Specific Problem

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

 

Motor runs and pump cycles,

Intake valve or outlet valve is

Remove and clean inlet valves and outlet valves.

 

 

but pressure does not build up.

not seating properly.

Replace if necessary. See List of Kits, page 26.

 

 

 

 

 

 

 

 

Pump packings are worn or

Check for leaking around pump.

 

 

 

damaged.

ProX7 and ProX9: Replace pump packings. See

 

 

 

 

 

 

 

 

List of Kits, page 26.

 

 

 

 

X5 and X7: Replace complete pump. See List of

 

 

 

 

Kits, page 26.

 

 

 

 

 

 

 

 

 

 

General Problem: Excessive Pressure Build Up

 

 

 

 

 

 

 

 

 

 

 

 

Specific Problem

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

 

Prime/Spray Valve actuates

Pressure control switch has

Replace pressure control switch using Pressure

 

 

automatically, relieving

pinched wires.

Control Switch Kit, page 26.

 

 

pressure through drain tube.

 

 

 

 

Water or paint entered

Use Pressure Control Switch Kit, to replace

 

 

 

 

 

 

pressure control switch or

switch. See List of Kits, page 26.

 

 

 

shorted control board.

 

 

 

 

 

 

 

 

 

Control board failed.

See Control Board Diagnostics, page 25.

 

 

 

 

Replace damaged control board using Control

 

 

 

 

Board Kit, page 26.

 

 

 

 

 

 

 

22

312667B

Page 22
Image 22
Graco Inc 261820 specifications General Problem Excessive Pressure Build Up, Control Switch Kit