![](/images/new-backgrounds/1150067/150067107x1.webp)
Basic Troubleshooting / 基本故障排除 / 기본적인 문제 해결
English
Armature Short Circuit Spin | Armature, Brushes and | 2 Turn motor by hand | 3 If there is an uneven | ||
Test | Motor Wiring Open Circuit |
| (approximately two |
| resistance or no |
Quickly turn motor fan by | 1 Connect red and black |
| revolutions per second). |
| resistance, replace motor |
hand. There should not be | motor leads together with |
|
|
| using Motor Kit, page 60. |
electrical shorts and fan | test lead. |
|
|
|
|
should coast two or three |
|
|
|
|
|
revolutions before stopping. |
|
|
|
|
|
If fan does not spin freely, |
|
|
|
|
|
armature is shorted. Replace |
|
|
|
|
|
motor using Motor Kit, |
|
|
|
|
|
page 60. |
|
|
|
|
|
|
|
|
|
|
|
中文 |
|
|
|
|
|
|
|
|
|
|
|
电枢短路旋转测试 | 电枢、电刷和电动机接线开路 | 2 | 用手转动电动机 | 3 | 如果阻力不均匀或没有 |
用手快速转动电动机风扇。 | 1 将电动机的红色和黑色引 |
| (速度约为每秒两圈)。 |
| 阻力,则用电动机配件 |
应没有电气短路,而且风扇在 | 线与测试引线连在一起。 |
|
|
| 包更换电动机,见第 |
停止以前应能靠惯性转动两或 |
|
|
|
| 60 页。 |
三圈。如果风扇不能自由地旋 |
|
|
|
|
|
转,说明电枢短路。用电动机 |
|
|
|
|
|
配件包更换电动机,第 60 页。 |
|
|
|
|
|
|
|
|
|
|
|
한국어 |
|
|
|
|
|
|
|
|
|
|
|
전기자 단락 회로 회전 | 전기자, 브러쉬와 모터 배선 | 2 | 손으로 모터 팬을 | 3 | 고르지 않은 저항이 |
테스트 | 개방 회로 |
| 돌립니다 ( 초당 약 |
| 있거나 저항이 없을때 |
손으로 모터 팬을 빠르게 | 1 테스트 리드로 빨간색 |
| 2 바퀴씩 ). |
| 모터 키트를 사용하여 |
돌립니다. 전기 단락이 없는 | 및 검정색 모터 리드를 |
|
|
| 모터를 교체합니다 |
것이며 , 팬이 멈추기 전에 | 연결합니다 . |
|
|
| (60 페이지 ). |
2 - 3 회 회전해야 합니다 . |
|
|
|
|
|
만일 팬이 자유롭게 회전하 |
|
|
|
|
|
지 않으면 전기자가 단락된 |
|
|
|
|
|
것입니다 . 이 경우 모터 키 |
|
|
|
|
|
트를 이용하여 모터를 교체 |
|
|
|
|
|
하십시오 (60 페이지 ). |
|
|
|
|
|
|
|
|
|
|
|
54 | 313797C |