Basic Troubleshooting / 基本故障排除 / 기본적인 문제 해결
General Problem: Excessive Pressure Build Up /
一般故障:压力过度积聚 /
일반적인 문제 : 압력이 과도하게 높음
Problem | Cause | Solution |
|
|
|
|
|
|
Prime/Spray valve actuates automatically, | Pressure control switch is worn. | Replace pressure control switch using |
relieving pressure through drain tube. |
| Pressure Control Switch Kit, page 60. |
|
|
|
| Water or paint entered pressure control | Clean out and/or dry out and retry. Replace if |
| switch or shorted control board. | necessary using Pressure Control Switch |
|
| Kit, page 60. |
|
|
|
| Control board failed. | See Control Board Diagnostics, page 55. |
|
| Replace damaged control board using |
|
| Control Board Kit, page 60. |
|
|
|
故障 | 原因 | 解决的办法 |
|
|
|
|
|
|
填料 / 喷涂阀自动开启,通过回流管释 | 压力控制开关已磨损。 | 用压力控制开关配件包更换压力控制开关, |
放压力。 |
| 第 60 页。 |
|
|
|
| 水或涂料进入压力控制开关或控制板短路。 | 清洗并/或干燥,然后再试。如果有必要, |
|
| 用压力控制开关配件包进行更换,第 60 页。 |
|
|
|
| 控制板故障。 | 见第 55 页的控制板的诊断。用控制板配件 |
|
| 更换已损坏的控制板,第 60 页。 |
문제점 | 원인 | 해결 방안 |
|
|
|
|
|
|
프라임 / 스프레이 밸브가 자동으로 가동 | 압력 제어 스위치가 마모되었습니다 . | 압력 제어 스위치 키트를 사용하여 압력 |
되면서 배수관을 통해 압력을 낮춥니다 . |
| 제어 스위치를 교체하십시오 (60 페이지 ). |
|
|
|
| 물 또는 페인트가 압력 제어 스위치에 | 청소하거나 말린 후 다시 시도하십시오 . |
| 들어갔거나 제어 보드가 단락되었습니다 . | 필요하면 압력 제어 스위치 키트를 사용하 |
|
| 여 교체하십시오 (60 페이지 ). |
|
|
|
| 결함이 있는 제어 보드 . | 제어 보드 진단을 참조하십시오(55페이지). |
|
| 제어 보드 키트를 사용하여 손상된 제어 |
|
| 보드를 교체하십시오 (60 페이지 ). |
|
|
|
313797C | 51 |