Troubleshooting

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

HOW TO CHECK

 

 

 

 

 

 

Sprayer does not run at all

Control is commanding motor to run

6. Perform Field Short Test: Test at large 4-pin motor

 

but motor shaft does not rotate.

field connector. There should not be continuity from

Digital display shows E=05

Possibly locked rotor condition,

pin 4, the ground wire, and any of the remaining

 

 

an open connection exists between

3 pins. If motor field connector tests fail,

 

motor and control, there is a problem

replace motor.

 

with motor or control board, or

7. Check Motor Thermal Switch: Unplug thermal

 

motor amp draw is excessive.

 

 

wires. Set meter to ohms. Meter should read the

Control board status light blinks

 

 

proper resistance for each model (see table below).

5 times repeatedly

 

 

 

 

 

100k ohm

-

 

ti13140a

Resistance Table:

695

0 ohms

795

2k ohms

1095

3.9k ohms

MARK V

3.9k ohms

16

311365G

Page 16
Image 16
Graco Inc ti13460a, 311365G, ti13459a, ti13450a, ti13461a important safety instructions 100k ohm