| Troubleshooting | ||
|
|
|
|
|
|
|
| ||
TYPE OF PROBLEM | WHAT TO CHECK |
|
| HOW TO CHECK | |||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
Sprayer does not run at all | Allow sprayer to cool. If sprayer runs | NOTE: Motor must be cooled down for the test. | |||||||
| when cool, correct cause of |
|
|
|
|
|
|
| |
Digital display shows E=06 | 1. | Check thermal device connector (yellow wires) | |||||||
overheating. Keep sprayer in cooler | |||||||||
| |||||||||
| location with good ventilation. Make |
| at control board. |
|
|
| |||
|
|
|
|
|
|
|
| ||
| sure motor air intake is not blocked. | 2. Disconnect thermal device connector from control | |||||||
| If sprayer still does not run, follow |
| board socket. Make sure contacts are clean and | ||||||
Control board status light blinks | Step 1. |
| secure. |
|
|
| |||
6 times repeatedly |
| 3. Measure resistance of the thermal device. If reading | |||||||
|
| ||||||||
|
|
| is not correct, replace motor. | ||||||
|
|
| Check Motor Thermal Switch: Unplug thermal | ||||||
|
|
| wires. Set meter to ohms. Meter should read the | ||||||
|
|
| proper resistance for each model (see table below). | ||||||
|
|
|
| 100k ohm |
|
|
| ||
|
|
| - |
|
|
|
| ||
|
|
|
| ti13140a |
|
|
| ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
| Resistance Table: |
| ||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
| 695 |
| 0 ohms |
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
| 795 |
| 2k ohms |
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
| 1095 |
| 3.9k ohms |
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
| MARK V |
| 3.9k ohms |
| ||
|
|
|
|
|
|
| |||
|
| 4. Reconnect thermal device connector to control | |||||||
|
|
| board socket. Connect power, turn sprayer ON and | ||||||
|
|
| control knob 1/2 turn clockwise. If sprayer does not | ||||||
|
|
| run, replace control board. | ||||||
|
|
|
|
|
|
|
|
| |
Sprayer does not run at all | Check the connections. Control | 1. | Turn power OFF. |
|
|
| |||
| is not receiving a motor position |
|
|
|
|
|
|
| |
Digital display shows E=09 | 2. Disconnect motor position sensor and inspect for | ||||||||
sensor signal | |||||||||
| |||||||||
|
| damage at connectors. | |||||||
|
|
| |||||||
|
| 3. | Reconnect sensor. |
|
|
| |||
|
| 4. Turn power ON. If error continues, replace motor. | |||||||
Control board status light blinks |
| ||||||||
|
|
|
|
|
|
|
| ||
9 times repeatedly |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
Sprayer does not run at all | Check to see if control board is over | 1. | Make sure motor air intake is not blocked. | ||||||
| heating. |
|
|
|
|
|
|
| |
Digital display shows E=10 | 2. Make sure fan has not failed. | ||||||||
| |||||||||
|
| ||||||||
|
| 3. Make sure control board is properly connected | |||||||
|
|
| to back plate and that conductive thermal paste | ||||||
|
|
| is used on power components. | ||||||
Control board status light blinks |
|
| |||||||
| 4. | Replace control board. | |||||||
10 times repeatedly |
| ||||||||
|
|
|
|
|
|
|
| ||
|
| 5. | Replace motor. |
|
|
| |||
|
|
|
|
|
|
|
|
|
311365G | 17 |