Pressure Control Board
110 Vac U.K. Filter Board
Removal
Relieve pressure; page 9.
Wait 5 minutes before servicing.
1.Remove four screws (38) and cover (96).
2.Disconnect display connector (A) from motor control board (52).
3.Remove bottom two screws (39). Disconnect potentiometer connector (C) from motor control board (52). Disconnect filter board connector (J) and power cord connector (D) from ON/OFF switch (33). Remove control panel (68).
4.Disconnect motor board control power connectors (K) from filter board (146). Disconnect filter connector (L) from power cord connector (L).
5.Remove four screws (163) from filter board (146).
Installation
1.Connect motor control board power connectors (K) to filter board (146). Connect filter connector (L) to power cord connector (L).
2.Install filter board (146) with four screws (163).
3.Connect filter board power connector (J) and power cord connector (D) to ON/OFF switch (33).
4.Connect potentiometer connector (C) to motor control board (52).
5.Install control panel (68) with two screws (39).
6.Connect display connector (A) to motor control board (52).
7.Install cover (96) with four screws (38).
311365G | 25 |