Displacement Pump Replacement 1095/1595/Mark V

4.Close pump door and rotate latch into position. Do not tighten latch.

ti7329a

ti6313a

6.Tighten latch and rotate latch lock into locked position.

ti6204a

TI6312a

7. Attach drain hose to sprayer.

5.Rotate pump to align with paint hose. Connect paint hose and hand tighten to 70 in-lb.

ti6299a

ti7330a

8. Fill pump with Graco TSL until fluid flows onto top of seal.

ti5493a

38

311365G

Page 38
Image 38
Graco Inc ti13450a, 311365G, ti13460a, ti13459a, ti13461a Tighten latch and rotate latch lock into locked position