Pressure Control Board
Pressure Adjust Potentiometer
Removal
Relieve pressure; page 9. Wait 5 minutes before servicing.
1.Remove four screws (38) and cover (96). 96
38 | ti13493a |
2.Disconnect potentiometer connector (C) from motor control board (95).
95
C
ti12997a
3.Remove pressure control knob (34) with a hex wrench.
34
Installation
1.Install gasket (115), nut and potentiometer (82) on control panel (68). Torque nut to
68
82 | 82 |
| |
115 | ti12998a |
|
2.Install pressure control knob (34): Check pressure control knob alignment to potentiometer shaft. Turn shaft fully clockwise and attach knob in full ON position with a hex wrench.
34 | ti7258a |
3.Connect potentiometer connector (C) to motor control board.
95
C
ti12997a
4.Remove gasket (115), nut and potentiometer (82) from control panel (68).
68
82 | 82 |
| |
115 | ti12998a |
|
4.Install cover (96) with four screws (38). 96
38 | ti13493a |
311365G | 27 |