Installation

1.Install o-ring (20) and transducer (86) in filter base (67). Torque to 35-45 ft-lb (47-61 N•m). Install grommet onto transducer (86) and transducer into control box.

Pressure Control Board

3.Install control box (61) and control panel (68) with four screws (39).

4067

ti7447a

86

39

61

ti7458a

ti13494a

68

20

ti13496a

2.Connect transducer connector (E) to motor control board (95).

E

95

ti12999a

4.Connect potentiometer connector (C) to motor control board.

C

ti12997a

5. Install cover (96) with four screws (38).

96

38

ti13493a

 

311365G

29

Page 29
Image 29
Graco Inc ti13461a, 311365G, ti13460a, ti13459a, ti13450a Install control box 61 and control panel 68 with four screws