Repair

Repair

Follow Pressure Relief Procedure, page 9.

See Parts, page 16, for callout references.

Disassembly

1.Unscrew retaining ring (14) to remove air cap (13b). Check o-rings (13a and 13c) and replace if necessary.

2.Trigger gun while unscrewing nozzle (11) to prevent needle damage.

3.Check o-ring (19) and replace if necessary.

4.Remove fluid control valve (8), spring (26), needle (9), and nut (7). Inspect. Replace tip (9c), needle (9), and u-cup seal (20) as necessary. If replacing needle tip, use low strength thread adhesive on needle tip threads.

5.Remove spring (28) and push the air valve assembly (6) out the back of the gun. Inspect. Replace air valve assembly (6) and u-cup seal (20) as necessary. Use tool (33) to install u-cup seal.

6.Remove trigger nut (22), trigger pin (21), wave washer (18), and trigger (10).

7.Unscrew needle packing nut (17) and remove u-cup packing (16) and spreader (15).

8.Remove air control valve assembly (5). Inspect and replace as necessary.

9.Remove air inlet valve assembly (27). Inspect and replace as necessary.

NOTE: Do not remove the fluid inlet fitting.

It was attached to the gun body with per- manent thread locker. There is also no need to remove the air inlet fitting.

14

312414J

Page 14
Image 14
Graco Inc 312414J important safety instructions Repair, Disassembly, Follow Pressure Relief Procedure