Pressure Relief Procedure
Pressure Relief Procedure
To reduce the risk of injury, follow this Pressure Relief Procedure whenever you:
•Are instructed to relieve pressure
•Stop spraying
•Service equipment
•Install or clean spray nozzle
•Disconnect or connect hose
1.Turn OFF air inlet valve (E).
E
2. Open gun air valve (23).
23
TI
3. Trigger gun. Spray material back into hopper (G).
G
6 | 313384B |