Graco Inc D 5 4, D 5 D, D 5 B, D 5 5 Husky 515 and 716 Performance Charts, Air Consumption, 308981

Models: D 5 B

1 36
Download 36 pages 17.06 Kb
Page 35
Image 35
Air Consumption

Husky 515 and 716 Performance Charts

AIR CONSUMPTION––scfm (cubic meters/min)

 

Air Consumption

 

Test Conditions: Pump tested in water with inlet submerged.

30

A

(0.84)

 

Air Consumption Curves

Aat 100 psi (0.7 MPa, 7 bar) air pressure

25B at 70 psi (0.48 MPa, 4.8 bar) air pressure

(0.70)

C at 40 psi (0.28 MPa, 2.8 bar) air pressure

 

20

 

 

 

 

 

 

B

 

(0.56)

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

(0.42)

 

 

 

 

 

 

 

 

10

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

(0.28)

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

(0.14)

 

 

 

 

 

 

 

 

0

2

4

6

8

10

12

14

16

0

 

(7.6)

(15.2)

(22.7)

(30.3)

(37.9)

(45.4)

(53.0)

(60.6)

FLUID FLOW––gpm (lpm)

To find Pump Air Consumption (scfm or m#/min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):

1.Locate fluid flow rate along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve.

3.Follow left to scale to read air consumption.

308981 35