Graco Inc D 5 C, 716 Above-Ground Transfer Installation, Gallon Bung Pump Installation, 308981

Models: D 5 B

1 36
Download 36 pages 17.06 Kb
Page 7
Image 7
ABOVE-GROUND TRANSFER INSTALLATION

Installation

ABOVE-GROUND TRANSFER INSTALLATION

J

C D 55-GALLON BUNG PUMP INSTALLATION A AIR SPRAY INSTALLATIONVENTING EXHAUST AIR K

H

E Manual backgroundManual background B

F G

YN

L9074A

M

KEY

APump

BBleed-type master air valve (required for pump)

CElectrically conductive air supply line

DAir line quick disconnect

EMaster air valve (for accessories)

FAir line filter

GPump air regulator

HFluid drain valve (required)

JFluid regulator (optional)

KElectrically conductive fluid supply hose

LFluid suction line

MUnderground storage tank

NWall mounting bracket

YGround wire (required; see page 8 for installation instructions)

 

 

55-GALLON BUNG PUMP INSTALLATION

 

KEY

 

A

 

 

 

 

A

Pump

C

D

 

 

 

C

Electrically conductive air supply line

 

 

 

D

Air line quick disconnect

 

 

 

H

Fluid drain valve (required)

Y

 

AIR SPRAY INSTALLATION

K

Electrically conductive fluid supply hose

 

 

 

L

Fluid suction line

 

 

YGround wire (required; see page 8 for installation instructions)

 

 

 

 

S

 

 

 

 

 

E

P

KEY

 

 

 

 

R

 

 

 

 

A

Pump

 

 

 

 

 

F

 

D

A

T

C

Electrically conductive air line to pump

 

E

Gun air line shutoff valve

 

 

G

 

K

F

Air line filter

 

 

 

 

H

G

Gun air regulator

 

 

 

 

H

Fluid drain valve (required)

 

 

 

 

 

 

C

 

 

 

K

Electrically conductive fluid supply hose

 

 

 

 

P

Circulating valve

 

 

V

 

 

 

Y

 

 

R

Electrically conductive air line to gun

 

 

 

 

 

 

K

Manual background H

L

9075A

U

SAir spray gun

TElectrically conductive fluid return line

U 5-gallon pail

V Agitator

Y Ground wire (required; see page 8 for installation instructions)

9076A

VENTING EXHAUST AIR

KEY

W Muffler

Z

 

X Electrically Conductive Air Exhaust Hose

 

Z Container for Remote Air Exhaust

 

All wetted and non-wetted pump parts must be

W

compatible with the fluid being pumped.

 

X

Fig. 2

04054

 

308981 7

Page 7
Image 7
Graco Inc D 5 C, 716 Above-Ground Transfer Installation, Gallon Bung Pump Installation, Air Spray Installation, 308981