WARNING

HIGH PRESSURE SPRAYCAN CAUSE SERIOUS INJURY. FOR PROFESSIONALUSE ONLY. OBSERVE ALL WARNINGS.

Read and understand all instructionmanuals beforeoperating equipment.

FLUID INJECTION HAZARD

General Safety

This 'pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid through your skin and into your body and cause extremely serious bodily injury, including theneed for amputation. Also, fluid injected or splashed into theeyes oron the skin can cause serious damage. In addition, some cleaning solutions maybetoxicandcancausechemicalburns, skin irritations, and allergic reactions if inhaled orif they come in contact with the body or eyes. Always follow these precautions when operating your pressure washing system to reduce the risk of serious bodily injury.

NEVERpointthespraygunatanyoneoratanypartof

the body. NEVER use the spray gun without the wand. NEVER put hand or fingers over the spray tip.

NEVER try to stop or deflect leaks with your hand or body. .

ALWAYS be sure equipment safety devices are operating properly before each use.

Use this pump only for pumping water and water- diluted cleaning solutions. NEVER use the pump for paint or.any other coatings.

ALWAYS wear protective eyewear and appropriate clothing to protect yourself from the overspray and the debris that isremoved as you clean.

Read and follow the cleaning chemical manufacturer's recommendations on preparation and use of the cleaning solution, and the use of breathing apparatus and proper ventilation.

MEDICAL TREATMENT

If any fluid appears to penetrate your skin, get

EMERGENCY MEDICAL CARE AT ONCE. DO NOT TREAT AS A SIMPLE CUT. Tell the doctor exactly what fluid was injected.

Note To Physician: Injection in the skin is a traumatic injury.' It is important to treat the injury surgically as soon as possible. Do not delaytreatment to researchtoxicity. Toxicityisa concern with some exotic coatings injected directly into thebloodstream. Consultation with

aplastic surgeon . or reconstructive hand surgeon may be advisable.

Pressure Relief Procedure

To reduce the riskof serious bodily injury, including fluid injection and splashing in the eyes, or on the skin, always follow this procedure whenever you shut off the pump, when checking or servicing any part of the system. when installingor changing spray tips, and whenever you stop spraying for more than

10minutes.

1.Engage the guntrigger safety latch.

2.Turn pressure washer OFF.

3.Remove the power cord from outlet.

4.Shut off the water supply.

5.Disengagethe trigger safety latch andtriggerthe gun to relieve pressure, and engage the latch again.

Spray Gun Safety

Do not remove or modify any pait of the gun; this can cause a malfunction and result in serious bodily injury.

Safety Latch

ALWAYS engagethe gun safetylatchwhenever you

stopcleaning,evenforamoment.ThelatchMUSTBE

pushed fully down to make the gun inoperative. Failure to properly set the safety latch can result in accidental triggering of the gun. See Figure2.page 6.

Spray Tip Safety

Use extreme caution when cleaning or changing spray tips. If the spray tip clogs while spraying, engage the gun safety latch immediately. ALWAYS follow the Pressure Relief Procedure and then remove the spray tip to clean it.

2802-776

Page 2
Image 2
Graco Inc 800-232, 802-776 manual Fluid Injection Hazard

800-232, 802-776 specifications

Graco Inc. is a well-known manufacturer in the fluid handling industry, providing a diverse range of products designed to facilitate the efficient and safe transfer of fluids. Among its notable offerings are the Graco Inc. models 802-776 and 800-232, which cater to different applications requiring precision and reliability in fluid handling.

The Graco 802-776 is particularly recognized for its robust design and outstanding performance in high-pressure environments. This model is typically utilized in applications such as air-powered spray guns and paint distribution systems, making it ideal for professionals in the automotive, manufacturing, and construction industries. One of the main features of the 802-776 is its high flow rate, allowing users to complete tasks more efficiently. Additionally, the unit is equipped with a heavy-duty construction that minimizes wear and tear, thus extending its operational lifespan.

On the other hand, the Graco 800-232 is engineered for versatility, providing solutions for a variety of fluid types, including paints, coatings, and adhesives. This unit is highly adaptable, making it suitable for both industrial and commercial uses. A standout feature of the 800-232 is its compact design, which facilitates easy transport and maneuverability in tight spaces. Users appreciate its user-friendly interface, which simplifies operation, reducing the learning curve for new staff or operators.

Both models are equipped with advanced technologies that enhance functionality and safety. For instance, they include pressure control features that provide stability in fluid delivery, ensuring that users can achieve consistent results regardless of application conditions. Furthermore, Graco products are designed with durable materials, ensuring longevity and reliability over time, which is essential in demanding work environments.

Safety is also a critical aspect of the design for both models. They incorporate various safety features to minimize risks during operation, including automatic shut-off mechanisms and pressure relief valves. These technologies not only protect the equipment but also ensure the safety of the personnel operating them.

In summary, Graco Inc. models 802-776 and 800-232 are exemplary products that showcase the company's commitment to delivering high-quality fluid handling solutions. With their unique features, advanced technologies, and user-centric designs, these units are well-suited for a broad range of applications, addressing the demands of modern industries effectively.