Other Options and Accessories

Electrical

Disconnect Switches

Toggle type and heavy duty disconnect switches are available for positive electrical shut-off and safety in servicing fans. The following switches are available to meet individual electrical requirements and can be factory mounted or shipped loose for field mounting. Wiring from the motor to the disconnect box is provided with factory mounted disconnect switches.

NEMA-1 - General purpose

NEMA-3R - Rainproof

NEMA 4 - Watertight

NEMA-3R & NEMA 4 - Heavy Duty

NEMA-7 & 9 - for Class 1 and Class 2 hazardous locations.

1-Point Wiring

Available when the following items are selected: common voltages on the motor and the actuator, disconnect mounted and wired and a wall housing. The wires are pulled from the motor and the actuator on the damper to the disconnect box. (Hard wiring of the components to the disconnect switch is by others.)

Exception: When a specific voltage is not available on the actuator, Greenheck will provide a hard wired transformer to the actuator. Greenheck will then pull the wires from the transformer to the disconnect box.

UL/cUL 705

1-Point wiring Junction Box or Disconnect

NEMA-3R and NEMA-1

All belt and selected direct drive fans with TE standard efficiency, single speed motors are available with the UL705 listing for electrical.

Extended Wiring Pigtail

Available only in conjunction with factory mounted disconnect switches, liquid tight wiring pigtails allow direct hook-up to the power supply which eliminates field wiring at the fan. Internal or external power supply can be specified.

End Switches

Factory mounted end switches allow the damper to open completely before the fan is energized. This will reduce the back pressure and brake horsepower load on the fan motor at startup. (Field supplied motor starter with a relay is required to complete the wiring on a system using an end switch.)

Options

Coatings

A variety of special coatings ranging from enamels to phenolics are available for decorative or protective purposes. When a special coating is selected for the fan, all accompanying accessory items are also coated unless so specified. Consult your local representative for more details.

Welded and Painted Fan Construction

For applications where extra heavy construction is required, welded steel construction is available. With this option, all stationary connections which are normally bolted are welded and coated with an industrial grade paint. This option applies to belt drive level 3 fans and direct drive level 2 and 3 fans only.

Propeller Fan Rotation Guide

Propeller blade should cup and throw the air when rotating in the correct rotation as shown below.