Grindmaster LCD-2R Machine Fault Codes cont, “Engineer” Program Settings, 6: Water overheat, Page

Models: LCD-2R LCD-2A

1 20
Download 20 pages 47.69 Kb
Page 11
Image 11
Machine Fault Codes (cont.)

“Engineer” Program Settings

TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONLY

Machine Fault Codes (cont.)

6: Water overheat

The thermistor has detected the water is too hot. The boiler element contactor may have failed short circuit. The machine may be running high Wattage Power with a preheater.

7: Leak

If the machine refills 15 times without a dispense the machine assumes a leak. A water outlet valve may be leaking.

8: Inlet valve leak

Not available with single inlet valve machines

9: Tank thermistor fail

The thermistor has failed open circuit, or connections from the thermistor to the PCB may have failed.

10: Reset System

The watchdog timer on the control chip has timed out, the machine needs a reset. (Turn machine off, wait 5 sec- onds, turn back on).

Programming Guide for Calibration of Mix Ratio (refer to Figure D)

1.The water dump valves are factory set to 60 ml/sec (2 fl-ounces per second). If adjustment is required, disconnect power to the machine and remove the left side access plate to gain access to the dump valves.

2.Using an appropriate hex key, turn the adjustment screw on each dump valve clockwise to fully close the adjustor (Do not force the adjustment as permanent damage can occur to the valve)

3.Turn each dump valve adjustor counter clockwise as indicated below to achieve

(2)fl-ounce per second.

Top valve =

Left dispense head= 5.5 turns out CCW

Figure D

Middle valve=

Middle dispense head= 4.5 turns out CCW

Bottom valve =

Right dispense head= 4.0 turns out CCW

4. Reassemble machine and power ON.