SECTION 2: CIRCUIT REQUIREMENTS
Operation
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The motor for your machine may draw the follow- ing amps at maximum load.
G0513X at 220V | ............. 10 | Amps |
G0513X at 110V* | 20 | Amps |
G0514X at 220V | 16 | Amps |
G0514X3 at 220V | 9 | Amps |
G0514X3 at 440V | 4.5 | Amps |
Circuit Requirements
We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire
G0513X at 220V | 15 Amp Circuit Breaker |
G0513X at 110V* | 30 Amp Circuit Breaker |
G0514X | 20 Amp Circuit Breaker |
G0514X3 at 220V | 15 Amp Circuit Breaker |
G0514X3 at 440V** | 15 Amp Circuit Breaker |
*To run on 110V, you MUST rewire the motor. Refer to the wiring diagram on Page 54.
**To run on 440V, you must rewire the motor and replace the 220V magnetic switch assem- bly with the 440V magnetic switch assembly (Part #P0514X3161A). Refer to the wiring dia- gram on Page 58 for wiring details.
Plug Type
The cord set enclosed does not have a plug as the style of plug you require will depend upon the type of service you currently have or plan to install. We recommend using the following plugs for your machine on a dedicated circuit only (see Figures
G0513X at 220V | NEMA | ||
G0513X at 110V* | NEMA | Plug | |
G0514X | NEMA | Plug | |
G0514X3 at 220V | NEMA | Plug | |
G0514X3 at 440V** | NEMA | Plug | |
|
|
|
|
|
|
|
|
|
|
|
|
Figure 3. NEMA
Figure 4. NEMA
G0513X/G0514X/G0514X3 Extreme Series Bandsaw