Placement

Power Cord

The Model G0524 is a heavy machine that weighs approximately 1980 lbs. Serious per- sonal injury may occur if safe moving methods are not followed. Use the assistance of power equipment when moving the crate and placing the machine.

To remove the saw base unit from the crate pallet:

1.Cut off and remove all plastic straps from the crate.

2.Using a forklift, position the saw over the final location.

3.Place the cast iron feet under the leveling screws.

4.Lower the saw onto the cast iron feet as shown in Figure 13.

Leveling Screw (1 of 4)

Cast Iron Foot (1 of 4)

Figure 13. Cast iron feet.

5.Adjust the leveling screws until the saw table is level.

To connect the power cord to the saw:

1.Read through Section 3: Circuit Requirements to double-check that your setup follows the safety and circuit requirements, and that the power cord you use meets the minimum requirements for this machine.

2.Open the electrical panel box.

3.Feed the power cord through the strain relief on the side of the electrical panel, and connect the cord wires to the main terminal (Figure 14).

Figure 14. Main terminal located inside saw electrical panel.

4.Close the electrical panel door.

5.DO NOT connect the power cord to the power source at this time.

-16-

G0524 Rip Saw

Page 18
Image 18
Grizzly G0524 owner manual Placement Power Cord, To connect the power cord to the saw