6.Approximately 5 seconds after the arbor is started, press the FEED MOTOR START button. The conveyor track should start and run smoothly. Note—An automatic time delay prevents the conveyor track from starting up until 5 seconds after the main motor has started.

7.Press both the MAIN MOTOR STOP and the FEED MOTOR STOP buttons to turn the machine off.

8.Disconnect the machine from the power source.

9.Install the saw blade by reversing the steps in the “Remove the Blade” subsection on the previous page. Note—Make sure the blade is NOT making contact with any part of the conveyor track.

Scale Calibration

The distance between the right edge of the blade teeth and the fence face should be equal to the scale reading on the fence rail. The scale can be adjusted back and forth once the two Phillips head screws (Figure 15) are loosened.

Figure 15. Phillips head screws securing

the fence scale.

-18-

G0524 Rip Saw

Page 20
Image 20