Grizzly G0572 Filter Capacity, To calculate the recirculating rate for your, shop space

Models: G0572

1 32
Download 32 pages 40.59 Kb
Page 15
Image 15
Filter Capacity

Figure 5 shows an example of poor air circulation, where the air filter is placed too close to obstruc- tions. In this situation, the velocity of the air is lost and circulation is diminished.

Filter

Figure 5. Poor air circulation. Placed too close to the wall, the air circulation short cycles, leav- ing much of the room unfiltered.

Below is a list of things to keep in mind when selecting a spot for the air filter:

Study your shop layout and try to determine the best location for the hanging air filter. Air flow that is obstructed will cause a short cycle effect, producing unsatisfactory results. There must be a clearance of at least 12" from any obstructions in front and back of the unit.

Try to place the air filter in front of high dust producers like sanders or near areas where sanding will take place.

Do not place the hanging air filter where garage doors may pass closely or where it may impede transport or movement of any other object.

Try to place the unit where it is easy to access

for turning it on, cleaning and maintenance.

Filter Capacity

The G0572 Hanging Air Filter with Remote will

recirculate the entire volume of air in a room

measuring 25' X 25' X 8' approximately 12 times

in one hour. We recommend that the volume of

air in your room be recirculated at least 6-8 times

every hour.

 

 

 

 

 

 

To calculate the recirculating rate for your

shop space:

 

 

 

 

 

Step 1. Use the formula below to calculate how

long it takes to circulate all the volume of air in

your shop. The rate of air movement for the air

filter is 1044 cubic feet per minute.

W X L X H

= Minutes for circulating 1 time

1044

 

 

 

 

 

 

Example: 25' X 25'

X 8'

=

5000

= 4.79 Minutes

 

1044

 

 

 

 

 

 

1044

 

Step 2. Calculate how many times per hour the

volume is recirculated through the hanging air

filter by dividing 60 minutes by the circulating

time from Step 1. The result is listed as times per

hour.

 

 

 

 

 

 

Example:

60

= 12.52

Times per Hour

 

4.79

 

 

 

 

 

 