Beginning Mounting
You can install the air filter unit one of the following ways:
•
•Hanging Mount: Use the eye bolts (see Figures 6 & 7) for a high ceiling application. Refer to Page 16.
•Flush Mount: Use the flush mount flange brackets (see Figures 6 & 7) for a wall or low ceiling application. Refer to Page 17.
Hanging Mount
Eye Bolt
Flush Mount
Flange Bracket
Mount
Rubber Foot
Figure 6. Air filter unit mounting options.
Hanging Mount | |
Eye Bolt | Rubber Foot |
| Flush Mount |
| Flange Bracket |
Figure 7. Air filter unit mounting hardware.
!Keep the air filter unit unplugged during all
installation procedures. Ignoring this warning may result in serious personal injury to you or others!
|
|
Components and Hardware Needed | Qty |
Rubber feet | 4 |
Get lifting assistance before installation. At 64 pounds (shipping weight), the Model G0572 air filter is a heavy load.
You can use the air filter unit as a portable air filtration system by installing the rubber feet and placing the unit on a workbench or a table.
To set up the air filter for
1.With the help of an assistant, carefully invert the air filter unit.
2.Expose the sticky backing on the foot, and affix the rubber foot to the bottom of the air
filter unit, as shown in Figure 8.
G0572 Hanging Air Filter with Remote |