Troubleshooting
Symptom | Possible Cause | Possible Solution | ||
|
|
|
| |
The air filter does not operate at all. | 1. The power supply circuit breaker is | 1. | Correct the cause for high current | |
|
| tripped. |
| draw and close the circuit breaker. |
| 2. | No power to the control panel | 2. | Replace the blown fuse in the control |
| 3. | Wiring is at fault |
| panel. |
| 4. | The control panel circuit board is at | 3. | Repair, replace wires, plugs and |
|
| fault. |
| cables as applicable; and make sure |
| 5. | The motor is at fault. |
| all electrical plugs and connections |
|
|
|
| are secure. |
|
|
| 4. | Replace the circuit board. |
|
|
| 5. | Replace the motor. |
|
|
|
| |
The remote control does not operate the | 1. The remote control has no power. | 1. | Install or replace the batteries. | |
air filter but the control panel operates | 2. | The signal path is obstructed. | 2. | Make sure the signal path is clear to |
fine. | 3. | The remote control is at fault. |
| the infrared remote control sensor on |
|
| |||
| 4. | The control panel circuit board is at |
| the control panel. |
|
| fault. | 3. | Replace the |
|
|
|
| unit. |
|
|
| 4. | Replace the control panel circuit |
|
|
|
| board. |
|
|
|
| |
The air filter CFM output is reduced. | 1. The filters are wet or clogged. | 1. | Replace the primary filter and clean | |
| 2. | The airflow path is obstructed. |
| the secondary filter. |
| 3. | The control panel circuit board is at | 2. | Remove obstructions or add ducting. |
|
| fault. | 3. | Replace the control panel circuit |
| 4. | The motor is at fault. |
| board. |
|
|
| 4. | Replace the motor. |
|
|
|
|
|
The air filter unit is noisy or vibrates. | 1. | The mounting is loose. | 1. | Tighten the flange brackets and rein- |
| 2. | The unit is not level. |
| stall the air filter unit. |
| 3. | The fan or motor is loose. | 2. | Level the air filter unit. |
|
|
| 3. | Unplug the unit, remove the filters, and |
|
|
|
| tighten all loose fastners. |
|
|
|
|
|
Disconnect power to the machine when perform- ing any troubleshooting. Failure to do this may result in serious person- al injury.
G0572 Hanging Air Filter with Remote |