Hanging Mount

Flange Bracket Mounting

Rubber Feet

Holes

 

Figure 8. Rubber feet correctly installed

(Underside View).

3.Repeat Step 2 for remaining feet.

Note— For permanent table-top mounting, refer to the Flush Mount procedure on Page 17, and install the air filter unit to the tabletop with the flush mount flange brackets.

Hanging Mount

 

Components and Hardware Needed

Qty

Eye bolts

4

Chain, cable, or steel strapping lines

4

Tools Needed

 

Wrench 12mm

1

Get

lifting

assistance

before installation. At

64

pounds

(shipping

weight), the Model G0572

air filter is a heavy load.

To make the unit operate at the optimum height of 7' from the floor, you can install the air filter unit in your shop by hanging it by chain, cable, or steel strapping.

ONLY hang the air filter to load bearing ceil- ing studs or joists that can hold at least 100 lbs. DO NOT mount the unit to sheet rock, pressboard, paneling, or honeycomb ceil- ing panels with expansion-type fasteners like the ones shown in Figure 9. The fasten- ers can tear out and the air filter can fall. Ignoring this warning can result in severe injury or death.

Figure 9. Typical unacceptable fasteners.

To install the air filter for hanging mount operations:

1.Install four chain, cable, or steel strapping lines to your ceiling from capable ceiling joists or supports. When the lines hang down freely they should be 1514" from left-to-right and 2412" from front-to-rear. Optimally, the unit should hang 7' off the floor when finished.

-16-