SECTION 2: CIRCUIT REQUIREMENTS

110/220V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G1010 features a 12 HP 110/220V motor that is prewired at 110V.

Motor Draw at 110V

9

Amps

Motor Draw at 220V

4.5

Amps

Circuit Requirements

Only connect your machine to a circuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

110V Circuit

15 Amp

220V Circuit

15 Amp

-10-

Wiring for 220V

The Model G1010 can be rewired to operate on a 220V power source. The motor must be rewired according to the wiring diagram on the motor label. The wiring configuration can also be found on the inside of the motor wire cover, as well as on Page 38.

Plug Type

The Model G1010 comes prewired with a NEMA 5-15 plug. If you wish to rewire the motor to 220V you will need the following 220V plug (see Figure

2 for an example):

220V Plug & Receptacle

6-15

 

 

 

 

 

 

 

 

 

Figure 2. 6-15 plug and outlet.

G1010 4" x 6" Metal-Cutting Bandsaw

Page 12
Image 12
Grizzly G1010 instruction manual Circuit Requirements, 110/220V Operation, Wiring for