Test Run

Loose hair, clothing, or

jewelry could get caught

in machinery and cause

serious personal injury.

Keep these items away

from moving parts at all times to reduce this risk.

Once the assembly is complete, test run your power feeder to make sure it runs properly and is ready for regular operation. The test run consists of verifying that the motor powers up and runs correctly, and that the rollers operate.

Speed Dial

Feet Per

Minute

Scale

Meters Per

Minute

Scale

Feed Direction Rocker Switch

ON

OFF

If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately, then review Troubleshooting on Page 21.

If you still cannot remedy a problem, contact our Tech Support at (570) 546-9663 for assistance.

To test run the power feed:

1.Read the entire instruction manual first!

2.Make sure all tools and foreign objects have been removed from the tabletop area.

3.Make sure the speed dial (Figure 19) is pushed IN and turned all the way to the left.

4.Make sure the feed direction rocker switch (Figure 19) is in the central position.

Figure 19. Feed direction and speed dial.

5.Adjust the power feeder so all wheels are approximately 1" above the table surface.

6.Connect the power feeder to the power source.

7.Push the feed direction rocker switch to the left or right.

8.Pull the speed dial out until it stops and the power feeder will slowly turn. The power feed should run slowly and smoothly with little or no vibration.

9.Slowly turn the speed dial clockwise. The speed of the wheels should increase respec- tively.

10.Turn the speed dial back to zero, push the rocker switch to the other direction, and turn the speed dial clockwise again until the wheels turn. The wheels should turn the opposite direction from before.

11.Turn the power feeder OFF and move the rocker switch to the central position. The test run is complete.

-18-

Model G4173 18 HP Power Feeder

Page 20
Image 20
Grizzly G4173 1 8 HP owner manual Test Run, To test run the power feed