2.Place the 45° angle of your square against the blade. If the blade and square are not contacting evenly, Loosen the pointer as shown in Figure 19.
Table Parallelism
The G5045 table is
1.Place your miter gauge (set at 90°) in its slot, even with the front of the blade. Place a square between it and the side of the blade. See Figure 21.
2. Choose a tooth on the blade. close to the gauge. Mark the tooth with a felt tip pen. Bring marked tooth 1⁄2" above the table top. Set square to touch the marked tooth.
Figure 19. 45° check.
Figure 20. 45 degree stop collar.
3.Adjust the blade angle until the blade con- tacts the square evenly.
4.Advance the collar until it makes contact with the bracket . Figure 20.
5.Line up and fasen the pointer.
6.Reduce the blade tilt angle, then return it to the 45° position.
7.
Figure 21. Testing for table parallelism.
3.Slide the miter gauge toward the back of the saw until the square is at the trailing end of the blade. Keep square in place.
4.Turn the blade so marked tooth is 1⁄2" above the table at the back end of the blade. The square should touch the marked tooth.
|
|
|
|
|
|
|
|
G5045 10'' Bench |
| ||
|