SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

220V Three-Phase

G7209 Only:

The Model G7209 has a 5 H.P., 3450 R.P.M. motor which requires a 220V single-phase circuit. The cord set included does not have a plug, as the style of plug you require will depend upon the type of service you currently have or plan to install. The motor will safely draw about 30 amps at 220V under load. If you operate the G7209 on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist, and power failure still occurs, have the circuit inspect- ed by a qualified electrician.

In preparing to connect the Model G7209 to your existing or new circuit, it will be necessary to con- nect a plug that matches your 220V receptacle. If you will be installing a new receptacle and plug, we recommend using a NEMA-style 6L-30 plug and outlet shown in Figure 5.

The Model G7209 should be fused at 30 amps. Fusing at amperage ratings higher than 30 amps will not adequately protect the circuit.

Figure 5. 220V Single-Phase

G7210 Only:

The Model G7210 has a 71Ú2 H.P., 3450 R.P.M. motor which requires a 220V 3-phase circuit. The cord set enclosed does not have a plug, as the style of plug you require will depend upon the type of service you currently have or plan to install. The motor will safely draw about 22 amps at 220V under load. If you operate the G7210 on any cir- cuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist and power failure still occurs, have the circuit inspected by a qualified electrician.

In preparing to connect the Model G7210 to your existing or new circuit, it will be necessary to con- nect a plug that matches your 220V receptacle. If you will be installing a new receptacle and plug, we recommend using a HBL2711 30 A plug and outlet shown in Figure 6.

The Model G7210 should be fused at 30 amps. Fusing at amperage ratings higher than 30 amps will not adequately protect the circuit.

Figure 6. 220V 3-Phase

-8-

G7209/10 14'' Table Saw