4.With assistance, place the intake barrel over the large cyclone funnel and align the mount- ing holes as illustrated in Figure 17.
������
������
��������������
�����
��
������������������
������
Figure 17. Intake barrel and large cyclone funnel
mounting holes aligned.
NOTICE
When connecting parts that have a gasket applied to the mounting surface, always tighten the fasteners in a diagonal and rota- tional manner to ensure the gasket does not become crimped and compromise the seal.
5.Connect the intake barrel and large cyclone funnel with (12)
Intake |
Barrel |
Large Cyclone |
Funnel |
Figure 18. Intake barrel and large cyclone
funnel.
6.Install the four cyclone mounting brackets with (8) 3⁄8"-16 x 11⁄4" hex bolts, (16) 3⁄8" flat washers, and (8) 3⁄8"-16 lock nuts (see Figures 17 & 19).
Figure 19. Cyclone mounting bracket mounted
to collector assembly.
Blower Housing and Intake Barrel Assemblies
1.Apply the 3 x 6 x 2500mm gasket to the top mating surface of the intake barrel assem- bly.
2.Keeping the intake barrel assembly on the floor, lower the blower housing assembly over and approximately one inch away from the intake barrel assembly.
3.Using two punches or Phillips screwdrivers as alignment guides (see Figure 20), lower the blower housing assembly onto the intake barrel assembly.
Outlet
Port