Dust Collector Operation
Symptom | Possible Cause | Possible Solution | ||
Loud, repetitious | 1. | Dust collector is not on a flat surface and | 1. | Stabilize the dust collector. |
noise, or excessive |
| wobbles. |
|
|
vibration coming | 2. | Impeller is damaged and unbalanced. | 2. | Disconnect dust collector from power, and inspect |
from dust collector. |
|
|
| the impeller for dents, bends, loose fins. Replace |
|
|
|
| impeller if any damage is found. |
| 3. | The motor mounting or housing | 3. | Make sure all fasteners on the dust collector are |
|
| connections are loose. |
| tight. |
| 4. | Impeller is loose on the motor shaft. | 4. | Replace the motor and impeller as a set if the |
|
|
|
| motor shaft and the impeller hub are damaged. |
| 5. | Motor fan cover is dented, causing the | 5. | Replace motor fan cover. |
|
| motor fan to hit the cover while spinning. |
|
|
|
|
|
|
|
Dust collector does | 1. | Dust collection bags are full. | 1. | Empty collection bags. |
not adequately | 2. | Filter is dirty. | 2. | Clean filter. |
collect dust | 3. | There is a restriction in the duct line. | 3. | Remove dust line from dust collector inlet and |
or chips; poor |
|
|
| unblock the restriction in the duct line. A plumbing |
performance. |
|
|
| snake may be necessary. |
| 4. | The dust collector is too far away from | 4. | Relocate the dust collector closer to the point of |
|
| the point of suction, or there are too many |
| suction, and rework ducting without sharp bends. |
|
| sharp bends in the ducting. |
| Refer to Designing the System, beginning on |
|
|
|
| Page 28. |
| 5. | The lumber is wet and dust is not flowing | 5. | Process lumber with less than 20% moisture |
|
| through the ducting smoothly. |
| content. |
| 6. | There is a leak in the ducting, or a series | 6. | Rework the ducting to eliminate all leaks. Close |
|
| of small leaks, or too many open ports. |
| dust ports for lines not being used. Refer to |
|
|
|
| Designing the System beginning on Page 28 for |
|
|
|
| more solutions. |
| 7. | There are not enough open branch lines at | 7. | Open 1 or 2 more blast gates to different branch |
|
| one time, thereby causing a velocity drop |
| lines to allow the velocity in the main line to |
|
| in the main line. |
| increase. |
| 8. | The ducting and ports are incorrectly | 8. | Reinstall correctly sized ducts and fittings. Refer to |
|
| sized. |
| Designing the System beginning on Page 28 for |
|
|
|
| more solutions. |
| 9. | The machine dust collection design is | 9. | Use a dust collection nozzle on a stand. |
|
| inadequate. |
|
|
| 10. | The dust collector is too small for the dust | 10. | Install a larger dust collector to power your dust |
|
| collection system. |
| collection system. |
|
|
|
|
|
Sawdust being | 1. | Duct clamps or dust collection bags are | 1. | |
blown into the |
| not properly clamped and secured. |
| sure duct and bag clamps are tight and completely |
air from the dust |
|
|
| over the ducts and bags. |
collector. | 2. | Cylinder or funnel seals are loose or | 2. | Retighten all mounting and sealing points, replace |
|
| damaged. |
| damaged gaskets. |
|
|
|
|
|
G0637/G0638 Cyclone Dust Collector |