SECTION 6: MAINTENANCE
To reduce risk of shock or accidental startup, always disconnect equipment from power before adjustments, maintenance, or service.
Schedule
For optimum performance from your tool, follow this maintenance schedule and refer to any spe- cific instructions given in this section.
Daily Check:
•Damaged spray gun components.
•Worn or damaged wires/cables.
•Any other unsafe condition.
Daily Maintenance:
•Clean the tool.
•Check/replace moisture filter.
Model T25100 (Mfg. Since 8/12)
Cleaning
Cleaning the Model T25100 is simple and straight- forward.
To clean the Model T25100:
1.DISCONNECT TOOL FROM POWER!
2.DISCONNECT TOOL FROM AIR!
3.Ground the spray gun conductor pole to the grounding clip to remove any residual electri- cal charge.
4.Put on eye, lung, and skin protection.
5.Put uncontaminated powder back into the original container and store it in a dry, stable environment.
6.In a