6.PRINTER INSTALLATION (OPTIONAL)

11.Plug in the printer control cable to the printer assembly.

12.Wire the printer power supply wire to the printer assembly. Connect the red wire to #1, green wire to #2. See Decals by connector.

13.To mount the plenum thermocouple, cut a hole in the plenum 1-1/4” diameter within fifty

(50)feet of the control box. Secure the liquidtite and thermocouple using conduit clamps. Wire the sensor into the back connector pin #5 to white, pin #6 to red. See Figure 6A.

14.To mount the weather sensor, feed the cable through the 1-3/32" diameter hole in the bottom of the control box and secure with the electrical screw bushing. Have the sensor on the outside of the control box. Wire the cable to the black 36 pin connector, pins 7 through 11. (See Figure 6A).

15.Put cable ties approximately every four (4)" to hold all the loose wires and cables in place. Do not tie any of these wires to the AC leads. Cut off the cable tie ends.

16.Remove the printer interface card DMC4 from its shipping box and install it in the new card slot with the black connector to the bottom. DO NOT lay this control card on any steel or conductive material.

17.Remove the shipping tape from the printer paper and spool.

Figure 6B Sample Printer Readout

PNEG-1153 CALC-U-DRI Moisture/Matic/Manager

23