4. INSTALLATION

2.Position the sensor connecting band on the discharge tube so that the rectangular hole is toward the discharge end. Mark the outline of the rectangular hole and the edges of the band on the discharge auger tube. Cut a hole in the discharge tube eight (8)" long so the outline of the rectangular hole is removed (stay inside the total overall length marks of the band). Cut up one side of the discharge tube about one third (1/3) of the way around the tube. This extra room is for ease of removing flighting in the next step. (See Figure 4B).

3.Replace the connecting band on the discharge tube in the same position as in Step 2 (above) and mark the flighting at each end of the rectangular hole. Weld the discharge auger flighting to the shaft 3/8" beyond each of the marks. After the flight is welded at these points, cut out six and one half (6-1/2)" of the flighting all the way to the center shaft.

4.Smooth all the rough edges from the cut area and position the sensor hole centered over the six and one half (6-1/2)" area, then tighten the connecting band.

5.Before installing the sensor, see Sensor Installation page 14.

Sensor Cut-Out for Flat Bottom Discharge Units

CAUTION

DISCONNECT POWER TO THE AUGER MOTOR BEFORE PROCEEDING ANY FURTHER!

1.Determine where the sensor can be located. (See Figure 4D). There must be at least one full pitch of flight before and after the sensor. (See Figure 4E).

Figure 4D

PNEG-1153 CALC-U-DRI Moisture/Matic/Manager

9