4. INSTALLATION
Figure 4G
5.On the flat bottom pan, make some filler pieces 12" long to keep the grain closer to the sensor flag. See Figure 4G, See Figure 4H, and See Figure 4I. Be sure the leading edge is closed so grain cannot get under the pieces. Weld the pieces in place as shown. (See Figure 4G).
6.Remount the pan and check all the clearances and alignments. Before installing the sensor, insert the clearance gauge into the cutout. (See Figure 4J).
Figure 4H
Figure 4I
11 |