MZ-N10

• Description of error indication codes

Problem

 

Indication code

 

Meaning of code

Simple display

Description

 

 

 

 

 

 

 

No error

 

00

 

No error

---

No error

 

 

 

 

 

 

 

 

 

 

 

01

 

Illegal access target

Adrs

Attempt to access an abnormal address

 

 

 

 

address was specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Servo system error

 

02

 

High temperature

Temp

High temperature detected

 

 

 

 

 

 

 

 

 

 

 

03

 

Focus error

Fcus

Disordered focus or can not read an address

 

 

 

 

 

 

 

 

 

 

 

04

 

Spindle error

Spdl

Abnormal rotation of disc

 

 

 

 

 

 

 

 

 

 

 

11

 

TOC error

TOC

Faulty TOC contents

 

 

 

 

 

 

 

TOC error

 

12

 

Data reading error

Data

Data could not be read at SYNC

 

 

 

 

 

 

 

 

 

 

 

13

 

TOC address error

Tadr

TOC address data error

Power supply system error

 

22

 

Low battery

LBat

Momentary interruption detected

 

 

 

31

 

Offset error

Ofst

Offset error

 

 

 

32

 

Focus error ABCD

ABCD

Focus error ABCD offset error

 

 

 

 

offset error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

 

Tracking error

TE

Tracking error Offset error

Offset system error

 

 

Offset error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

X1 tracking error

X1TE

X1 tracking error Offset error

 

 

 

 

Offset error

 

 

 

 

 

 

 

 

 

 

35

 

MD DATA 2

MD2

MD DATA 2 disc error

 

 

 

 

Disc error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

 

Mirror error

Mirr

Mirror decision retry over

 

 

 

 

 

 

 

• Description of indication history

 

 

 

 

 

 

 

 

 

 

 

History code number

 

 

Description

 

 

 

1

 

The first error

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

The last error

 

 

 

 

 

 

 

 

 

 

 

 

N1

 

One error before the last.

 

 

 

 

 

 

 

 

 

 

 

N2

 

Two errors before the last.

 

 

 

 

 

 

 

 

 

 

 

 

R_

 

Total recording time

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset the Error Display Code

After servicing, reset the error display code.

Setting method of reset the error display code

1. Set the test mode (see page 11).

2. Turning the jog dial (down) or pressing the [DISPLAY] key on the remote commander activates the self-diagnosis result dis- play mode.

3. To reset the error display code, press the zREC. key or

key on the remote commander (twice) when the code is displayed (except “R_****”).

Remote commander LCD display (Key pressing at the first time)

000C l r O K ?

Remote commander LCD display (Key pressing at the second time)

000E r r C L R

(All the data on the 1, N, N1, and N2 will be reset)

14

Page 14
Image 14
Sony MZ-N10 service manual L r O K ?, R r C L R, Reset the Error Display Code