5.The display changes a shown below each time the jog dial (down) is turned or the [DISPLAY] key on the remote commander is pressed.

• Address & Adjusted Value Display

Remote commander LCD display

011C 6 8 S 0 1

 

 

 

 

 

 

 

address

 

 

adjusted value

 

 

item number

• Jitter Value & Adjusted Value Display

Remote commander LCD display

011O F F J 0 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jitter

 

value

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

item number

 

 

 

 

 

 

 

 

 

 

• Block Error Value & Adjusted Value Display

Remote commander LCD display

0110 6 3 B 0 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

block error

 

 

 

 

adjusted value

item number value

 

 

 

 

 

 

 

 

 

• ADIP Error Value & Adjusted Value Display

Remote commander LCD display

0110 5 9 A 0 1

 

 

 

 

 

 

 

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADIP error

 

 

 

 

 

 

 

 

 

item

number value

 

 

 

 

 

 

 

 

 

 

• Focus Drive Value & Adjusted Value Display

Remote commander LCD display

0110 1 5 F 0 1

 

 

 

 

 

 

 

 

Focus drive

 

 

adjusted value

 

 

item number value

• Item Title Display

Remote commander LCD display

 

011 LrefPw

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

item

 

title

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

item

number

 

 

 

 

 

 

However in the power mode (item number 700’s), only the item is displayed.

6.Quit the manual mode, and press the x key to return to the test mode (display check mode).

Overall Adjustment Mode

Mode to adjust the servo automatically in all items.

Normally, automatic adjustment is executed in this mode at the repair.

For further information, refer to “SECTION 5 ELECTRICAL ADJUSTMENTS” (see page 17).

MZ-N10

Self-Diagnosis Result Display Mode

This set uses the self-diagnostic function system in which if an error occurred during the recording or playing, the mechanism control block and the power supply control block in the microcomputer detect it and record its cause as history in the nonvolatile memory.

By checking this history in the test mode, you can analyze a fault and determine its location.

Total recording time is recorded as a guideline of how long the optical pick-up has been used, and by comparing it with the total recording time at the time when an error occurred in the self- diagnosis result display mode, you can determine when the error occurred.

Clear both self-diagnosis history data and total recording time, if the optical pick-up was replaced.

Self-diagnosis result display mode setting method

1.Set the test mode (see page 11).

2.In the display check mode, turning the jog dial (down) or press- ing the [DISPLAY] key on the remote commander activates the self-diagnosis result display mode where the LCD display as shown below.

Remote commander LCD display

0XX 1 0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total recording time

 

 

 

history code

 

 

 

 

 

 

 

 

 

 

 

when error occurred

error display code

 

 

 

Set LCD display

0XX

1 0000

Total recording time when error occurred

error display code

history code

3.Then, each time the > key is pressed, LCD display descends by one as shown below. Also, the LCD display ascends by one when the . key is pressed.

1

0XX 1 ****

0XX N ****

0XX N1****

0XX N2****

0XX R _ ****

XX

: Error code

1

* * * * : Total recording time

If the jog dial (down) is turned or the [DISPLAY] key on remote commander is pressed with this display, the LCD switches to the simple display mode.

4.Quit the self-diagnosis result display mode, and press the x key to return to the test mode (display check mode).

13

Page 13
Image 13
Sony MZ-N10 011C 6 8 S, 011O F F J, 0110 6 3 B, 0110 5 9 A, 0110 1 5 F, LrefPw, 0XX 0XX N 0XX N1 0XX N2 0XX R