Sony MZ-N10 SECTION TEST MODE, Outline, Setting Method of Test Mode, Releasing the Test Mode

Models: MZ-N10

1 66
Download 66 pages 37.19 Kb
Page 11
Image 11
MZ-N10

MZ-N10

SECTION 4

TEST MODE

Outline

This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be auto- matically adjusted.

Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key.

For the LCD display, the LCD on the remote commander is shown, but the contents of LCD display on the set are same. (Both displays may be displayed.)

Setting Method of Test Mode

There are three different methods to set the test mode:

1Short SL803 (TEST) on the MAIN board with a solder bridge (connect pin <zx. of IC801 to the ground) and turn on the power.

– MAIN Board (Side B) –

IC801

TP1829

R838

C815

1 - 6 8 6 - 3 4 7 -

SL803 (TEST)

3In case of setting the test mode by keys on the set and remote commander:

In the normal mode, turn on the [HOLD] switch on the set. While pressing the x key on the set, press the keys on the remote commander with the following order:

>t > t . t . t > t

.t > t . t OutlineSetting Method of Test Mode– MAIN Board (Side B) –Operation in Setting the Test Mode t Releasing the Test ModeManual backgroundManual backgroundManual background

Note: If electrical adjustment (CD and MO overall adjustment) has not been finished completely, “ERROR” is displayed on LCDs of the set and the remote commander.

Operation in Setting the Test Mode

When the test mode becomes active, first the display check mode is selected.

Other mode can be selected from the display check mode.

When the test mode is set, the LCD repeats the following dis- play.

Remote commander LCD display

All lit

All off

Microcomputer

versionManual backgroundManual backgroundManual backgroundManual backgroundV1.100 display

Set LCD display

All lit

All off

Microcomputer

001

 

version

Ver 1.100

display

 

2In case of setting the test mode only by keys on the set:

In the normal mode, turn on the [HOLD] switch. While press-

ing the [GROUP] key press the following order:

>t > t . t . t > t

. t > t . t X t X

When the X key is pressed and hold down, the display at that time is held so that display can be checked.

Releasing the Test Mode

For test mode set with the method 1:

Turn off the power and open the solder bridge on SL803 (TEST) on the MAIN board.

Note: Remove the solders completely. Remaining could be shorted with the chassis, etc.

For test mode set with the method 2 or 3:

Turn off the power.

11

Page 11
Image 11
Sony service manual MZ-N10 SECTION TEST MODE, Outline, Setting Method of Test Mode, Operation in Setting the Test Mode