| Advanced Troubleshooting | |
|
|
|
|
|
Specific Problem | Cause |
| Solution | |
|
|
|
|
|
|
|
|
|
|
Building circuit breaker opens | Sprayer electrical cord is | 1. | Unplug sprayer electrical cord. | |
as soon as sprayer is plugged | damaged | 2. | Disconnect black electrical cord wire at | |
into outlet and sprayer is NOT |
|
| power switch | |
turned on. |
| 3. | Unplug | |
NOTE: Remove enclosure |
| 4. | Plug in electrical cord | |
mounting screws and pull |
| 5. | Test voltage between black and white | |
enclosure away from drive |
|
| wires. Meter must read | |
housing. Take care not to pull |
| 6. | Replace electrical cord if no voltage. | |
on leads from electrical cord |
|
|
|
|
and power switch. | Sprayer power switch damaged | 1. | Unplug sprayer electrical cord. | |
|
| 2. | Disconnect black control board wire at | |
|
|
| power switch. | |
|
| 3. | Check resistance of switch with ohmmeter. | |
|
| 4. | Reading must be infinity with power switch | |
|
|
| OFF. | |
|
| 5. | Reading must be zero with power switch | |
|
|
| ON. | |
|
| 6. | Replace power switch if damaged. | |
|
|
|
| |
| Also “Basic Electrical Problems” and “Sprayer Wiring Problems”, page 12. | |||
|
|
|
| |
| ||||
General Problem: Erratic Motor Operation |
| |||
|
|
|
|
|
|
|
|
| |
Specific Problem | Cause |
| Solution | |
|
|
| ||
|
|
| ||
Sprayer quits after running for | Electrical outlet is damaged | Reset building circuit breaker or replace building | ||
5 to 10 minutes |
| fuse. |
|
|
|
|
| ||
| Electrical outlet supplying | Try another outlet. Check electric supply with volt | ||
| wrong voltage | meter. Meter must read | ||
|
| is too high, do not use outlet until corrected. | ||
|
|
| ||
| Also “Basic Electrical Problems” and “Sprayer Wiring Problems”, page 12. | |||
|
|
| ||
| Motor is overheating | “Motor is Hot”, page 10. | ||
|
|
|
|
|
14 | 309477F |