Grounding and Electrical Requirements

Grounding and Electrical Requirements

This sprayer requires 220-240 VAC, 50/60 Hz, 10A circuit with a grounding receptacle. Do not use an outlet that is not grounded.

ti2021a

Do not use the sprayer if the electrical cord has a damaged ground prong. Only use an extension cord with an undamaged 3-prong plug.

ti2022a

Only use an extension cord with an undamaged 3-prong plug. Recommended extension cords for use with this sprayer are:

15 m (49.2 ft) 1.0 mm2

30 m (88.4 ft) 1.5 mm2

50 m (164.0 ft) 2.5 mm2

Smaller-gauge or longer extension cords may reduce sprayer performance.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Thermal Overload

Motor has a thermal overload switch to shut itself down if overheated.

WARNING

To reduce risk of injury from motor starting unex- pectedly when it cools, always turn power switch OFF if motor shuts down.

309477F

7