Advanced Troubleshooting

General Problem: No Output

Specific Problem

Cause

Solution

 

 

 

 

 

 

Power switch is on and sprayer

See Basic Troubleshooting,

 

is plugged in but pump does

page 9.

 

not cycle

 

 

 

 

 

Motor runs but pump does not

Gear and/or yoke are damaged

Replace gear and yoke using Gear/Yoke Repair

cycle

(XR9 only)

Kit, page 18.

 

 

 

Motor does not run

Water or paint entered

Clean out and/or dry out and retry. Replace if

 

pressure control switch or

necessary using Pressure Control Switch Kit,

 

shorted control board

page 18.

 

 

 

General Problem: Excessive Pressure Build Up

Specific Problem

Cause

Solution

 

 

 

 

 

 

Prime/Spray Valve actuates

Pressure control switch is worn

Replace pressure control switch using Pressure

automatically, relieving

 

Control Switch Kit, page 18.

pressure through drain tube.

 

 

Water or paint entered

Clean out and/or dry out and retry. Replace if

 

 

pressure control switch or

necessary using Pressure Control Switch Kit,

 

shorted control board

page 18.

 

 

 

 

Control board failed

See Control Board Diagnostics, page 19.

 

 

Replace damaged control board using Control

 

 

Board Kit, page 18.

 

 

 