Advanced Troubleshooting
General Problem: No Output
Specific Problem | Cause | Solution |
|
|
|
|
|
|
Power switch is on and sprayer | See Basic Troubleshooting, |
|
is plugged in but pump does | page 9. |
|
not cycle |
|
|
|
|
|
Motor runs but pump does not | Gear and/or yoke are damaged | Replace gear and yoke using Gear/Yoke Repair |
cycle | (XR9 only) | Kit, page 18. |
|
|
|
Motor does not run | Water or paint entered | Clean out and/or dry out and retry. Replace if |
| pressure control switch or | necessary using Pressure Control Switch Kit, |
| shorted control board | page 18. |
|
|
|
General Problem: Excessive Pressure Build Up
Specific Problem | Cause | Solution | |
|
|
| |
|
|
| |
Prime/Spray Valve actuates | Pressure control switch is worn | Replace pressure control switch using Pressure | |
automatically, relieving |
| Control Switch Kit, page 18. | |
pressure through drain tube. |
|
| |
Water or paint entered | Clean out and/or dry out and retry. Replace if | ||
| |||
| pressure control switch or | necessary using Pressure Control Switch Kit, | |
| shorted control board | page 18. | |
|
|
| |
| Control board failed | See Control Board Diagnostics, page 19. | |
|
| Replace damaged control board using Control | |
|
| Board Kit, page 18. | |
|
|
|
309477F | 17 |