Flushina

+a

14.For a first-time flush, trigger the gun, and circulate the solvent for 20 seconds.

For flushina after soravina fluid, turn the 3-way valve to Circulate. Trigger the gun periodically whiie circulating the solvent. Periodically turn the 3-way valve to Drain to flush out some dirty sol- vent. Flush until the system is clean. Repeat with clean solvent, if necessary.

15.Raise the suction tube out of the solvent, trigger the gun, and run the pump until air comes from the gun. Turn the 3-way valve to Drain, and run the pump until all air is expelled.

16.Release the trigger, and close the fluid regulator (44) and the air regulators (6a,6b).

17.Clean the filter screen, air cap, and fluid nozzle separately.

18.Open the filter drain valve (48). Remove the filter bowl, and reinstall the filter screen.

19.Thoroughly clean the inside and outside of the

suction tube.

20.You are now ready to prime the system with another fluid or to store the system.

K E Y

 

 

 

A

Bleed-type master air valve

C

A i r l i n e

 

3

Fluid

heater

6 a

Pump

air

regulator

6 b

Gun

air

regulator

93-way valve

1 3 Drain hose

44 Fluid regulator

45 Fluid filter

48 Filter drain valve

Fig. 10

 

c --

 

 

 

 

308-448 1 1