A CAUTION
This equipment is compatible with most water based materials. See the wetted parts in the Tech- nical Data section and your fluid and solvent manufacturer’s compatibility information.
Do not use catalyzed materials in heated applica- tions.
I.Preparing the Operator
All persons who operate the system should be trained in the safe, efficient operation of all system compo- nents as well as the proper handling of the chemical coating. At a minimum, all operators should thoroughly read the safety, installation, and operation sections of this manual and the component manuals.
II.Preparing the Site
1 . Use at least a 5 HP (3.7 Kw) air compressor for efficient operation.
K E Y
Components you must supply:
A
B | Air | filter. |
|
| Order part no. 11 O - l 46, l/4 | npt(f) | |
C | Air | supply line |
|
D | Grounded 5 gallon metal pail | ||
E | Air line moisture trap |
|
Components supplied with package:
1Husky 307 pump
2G700N air spray gun
3Fluid heater
6 a Pump air regulator
6 b Gun air regulator
1 0 Whip hose
1 3 Drain hose
4 2 l/4” female quick
. disconnect coupler
4 3 Pump ground wire
4 4 Fluid regulator
4 5 Fluid filter
4 8 Filter drain valve
5 4 a Gun fluid hoses
5 4 b Gun air hose
5 8 T i e s t r a p
Fig. 1
2 . Clear obstacles and debris that could cause an unsafe operating environment.
3 . Bring an air line from your compressed air supply to the pump location. Be sure the air is dry and filtered. Install a
4 . Ventilate the spray booth.
To prevent hazardous concentrations of toxic and/ or flammable vapors, spray only in a properly venti- lated spray booth. Never operate the spray gun
~unless ventilation fans are operating.
Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.
/’
I-
4